Enzyme-linked immunoassay of rat endothelin 1 (ET-1)
This kit is for research use only.
Detection range: 96T
8μg / L -200μg / L
purpose of usage:
This kit is used to determine the content of ET-1 in rat serum, plasma and related liquid samples.
Experimental principle
This kit uses the double antibody sandwich method to determine the level of rat endothelin 1 (ET-1) in the specimen. Microporous plates were coated with purified rat endothelin 1 (ET-1) antibody to prepare solid-phase antibodies, and endothelin 1 (ET-1) was added to the monoclonal antibody-coated microwells in turn, followed by HRP-labeled The endothelin 1 (ET-1) antibody binds to form an antibody-antigen-enzyme-labeled antibody complex. After thorough washing, the substrate TMB is added for color development. TMB is converted into blue under the catalysis of HRP enzyme, and into the final yellow under the action of acid. The color depth is positively correlated with endothelin 1 (ET-1) in the sample. The absorbance (OD value) was measured with a microplate reader at a wavelength of 450 nm, and the concentration of rat endothelin 1 (ET-1) in the sample was calculated by a standard curve.
Kit composition
1
30 times concentrated washing solution
20ml × 1 bottle
7
Stop solution
6ml × 1 bottle
2
Enzyme reagent
6ml × 1 bottle
8
Standard product (400μg / L)
0.5ml × 1 bottle
3
Enzyme coated plate
12 holes × 8
9
Standard dilution
1.5ml × 1 bottle
4
Sample diluent
6ml × 1 bottle
10
Instructions
1 serving
5
Developer A liquid
6ml × 1 bottle
11
Sealing film
2 sheets
6
Developer B liquid
6ml × 1 / bottle
12
sealed bag
1
Specimen requirements
1. Specimens are extracted as soon as possible after collection, and extraction is performed according to relevant literature, and experiments should be conducted as soon as possible after extraction. If the test cannot be performed immediately, the specimen can be stored at -20 ℃, but repeated freezing and thawing should be avoided
2. The samples containing NaN3 cannot be detected because NaN3 inhibits horseradish peroxidase (HRP) activity.
Steps
1. Dilution of standard products: This kit provides one original standard product. The user can perform dilution in small test tubes according to the following chart.
200μg / L
Standard No. 5
150μl of original standard is added to 150μl standard dilution
100μg / L
Standard 4
150μl Standard No. 5 is added to 150μl standard dilution
50μg / L l
Standard 3
150μl Standard No. 4 is added to 150μl Standard Diluent
25μg / L
Standard No. 2
150μl Standard No. 3 is added to 150μl Standard Diluent
12.5μg / L
Standard 1
150μl Standard No. 2 is added to 150μl Standard Diluent
2. Sample addition: set up blank wells (the blank control wells do not add samples and enzyme reagents, the rest of the operation is the same), standard wells, sample wells to be tested. Accurately add 50μl of the standard on the enzyme-coated plate, add 40μl of sample diluent to the sample well, and then add 10μl of the sample to be tested (the final dilution of the sample is 5 times). Add the sample and add the sample to the bottom of the well of the microplate, try not to touch the wall of the well, shake gently to mix.
3. Incubation: Seal the plate with a sealing plate and incubate at 37 ° C for 30 minutes.
4. Mixing solution: dilute 20 times concentrated washing liquid with distilled water 20 times and reserve
5. Washing: Carefully peel off the sealing film, discard the liquid, spin dry, fill each well with the washing liquid, let it stand for 30 seconds and then discard, repeat 5 times and pat dry.
6. Add enzyme: add 50μl of enzyme label reagent to each well, except blank well.
7. Incubation: The operation is the same as 3.
8. Washing: The operation is the same as 5.
9. Color development: add 50μl of developer A to each well, then add 50μl of developer B, mix gently, and develop at 37 ° C in the dark for 15 minutes.
10. Termination: Add 50μl of stop solution to each well to stop the reaction (at this time the blue will turn to yellow).
11. Determination: Measure the absorbance (OD value) of each well in sequence with the blank air conditioner at zero and 450 nm wavelength. The measurement should be carried out within 15 minutes after adding the stop solution.
Summary of operating procedures:
Calculation
Taking the concentration of the standard as the abscissa and the OD value as the ordinate, draw a standard curve on the coordinate paper, and find the corresponding concentration from the standard curve according to the OD value of the sample; then multiply by the dilution factor; Calculate the linear regression equation of the standard curve with the OD value, substitute the OD value of the sample into the equation, calculate the sample concentration, and multiply it by the dilution factor to obtain the actual concentration of the sample.
Precautions
1. The kit should be equilibrated at room temperature for 15-30 minutes before being taken out of the refrigerated environment. If the enzyme label coated plate is unopened, the strip should be stored in a sealed bag.
2. Crystals may be precipitated in the concentrated washing liquid, which can be heated and dissolved in a water bath during dilution, and the results will not be affected during washing.
3. The sampler should be used at each step of sample addition, and the accuracy should be regularly checked to avoid test errors. It is best to control the sampling time within 5 minutes. If there are many specimens, it is recommended to use a volley gun to add samples.
4. Please make a standard curve at the same time of each measurement, it is best to make a double hole. If the content of the test substance in the specimen is too high (the OD value of the sample is greater than the OD value of the first well of the standard well), please first dilute it with a certain multiple (n times) of the sample diluent and then determine it. When calculating, please multiply the total dilution Multiple (× n × 5).
5. The sealing film is limited to one-time use to avoid cross-contamination.
6. Please keep the substrate away from light.
7. Strictly follow the instructions, and the test results must be determined by the microplate reader.
8. All samples, washing liquids and various wastes should be treated as infectious agents.
9. The components of different batches of this reagent shall not be mixed.
10. If there is any difference with the English manual, the English manual shall prevail.
Storage conditions and validity period
1. Kit storage :; 2-8 ℃.
2. Validity: 6 months

Manual Projector Screen

High Quality and Application Scenarios

The Aoxing Manual Pull Down Projector Screen has a spring mechanism that allows for smooth and effortless screen deployment. Its manual operation makes it a reliable, cost-effective choice for environments where automatic screens may not be necessary. Built with premium materials, this screen ensures long-lasting performance and is perfect for a wide range of settings.

Application Areas:

Business Offices

Classrooms & Training Rooms

Conference Rooms

Home Theaters

Event Spaces

Advantages of Manual Pull Down Projector Screen

Manual Operation: The simple spring-loaded mechanism allows for easy pull-down and retraction of the screen. No electricity or motor is needed, making it a cost-effective solution for many environments.
Easy to Install: The lightweight and simple design make installation quick and straightforward. It’s ideal for locations where a ceiling-mounted or permanently fixed screen isn’t feasible.
Durability: High-quality fabric surface that resists wear and tear, and keep the projection remains clear and consistent over time.
Space-Efficient: When not in use, the screen retracts neatly into its durable housing, saving the space.

Picture Clarity

The Manual Pull Down Projector Screen features a high-quality surface designed for optimal clarity. Whether you are projecting business presentations or full-length movies, the screen delivers crisp, sharp images that enhance your viewing experience.

Picture Contrast

The premium screen surface helps maintain excellent contrast, ensuring deep blacks and bright whites. Even in environments with moderate ambient light, this screen reduces washout, providing rich, detailed projections for both light and dark scenes.

Competitive Pricing and Bulk Ordering

Our Manual Pull Down Projector Screens are competitively priced, making them an excellent choice for wholesale and bulk orders. Whether outfitting a large office, educational institution, or conference center, our pricing ensures you get the best value for your investment. Bulk purchases are fully supported, and we are happy to provide assistance for large-volume buyers.

Customized Services

For customers with specific needs, we offer customized solutions. If you require a particular screen size or special features, our team is ready to work with you to create the ideal product for your space. Contact us to discuss your requirements and receive personalized service.

After-Sales Service

Warranty

A 1-year warranty could be available on the Manual Pull Down Projector Screens. If any manufacturing or design defects occur during the warranty period, our team will offer free returns or replacement of defective parts.

After-Sales Response

We ensure a 48-hour response time to emails, offering timely solutions to any inquiries. If the issue is related to product quality, maintenance and transportation costs will be covered during the warranty period.

Technical Support

Our after-sales team is available to offer professional support, helping you maximize the performance and longevity of your Manual Pull Down Projector Screen.

Roll Down Screen for Projector, Classroom Projector Screen, Roll Down Projector Screen, Ceiling Pull Down Projector Screen, Office Projector screen

Dongguan Aoxing Audio Visual Equipment CO.,Ltd , https://www.aoxingaudio.com